Place of Origin: | UK |
Brand Name: | MTL |
Certification: | CE |
Model Number: | MTL4501-SR |
Minimum Order Quantity: | 1pc |
---|---|
Price: | according to the purchase quantity |
Packaging Details: | carton |
Delivery Time: | approx. 4 weeks |
Payment Terms: | T/T payment |
Supply Ability: | 100pcs |
With the MTL4501-SR, a fail-safe switch/proximity detector located in the hazardous area can control an isolated fail-safe electronic output. The MTL4501-SR also provides relay alarm contacts to signal line-fault conditions. The MTL4501-SR is for use with approved fail-safe sensors in loops that require operation up to SIL3 according to the functional safety standard IEC 61508.
Part Number & Description For MTL4500 Series
Digital Input
MTL4501-SR 1ch DI failsafe solid-state output + LFD alarm
MTL4504 1ch DI relay output + LFD alarm + phase reversal
MTL4510 4ch DI solid-state output
MTL4510B 4ch DI multifunction solid-state output
MTL4511 1ch DI relay output
MTL4513 2ch DI solid-state output
MTL4514/B 1ch DI relay output + LFD alarm
MTL4516 2ch DI relay output
MTL4516C 2ch DI with changeover relay output
MTL4517 2ch DI relay output + LFD alarm
Digital Output
MTL4521 Loop powered solenoid driver
MTL4521L Loop powered solenoid driver IIC
MTL4523 Solenoid driver with LFD
MTL4523L Loop powered solenoid driver + LFD
MTL4523R Solenoid driver with LFD
MTL4523V/VL Solenoid/Alarm driver with voltage control
MTL4524 Switch operated solenoid driver
MTL4524S Switch operated solenoid driver, 24V override
MTL4525 Switch operated solenoid driver low power
MTL4526 2ch switch operated relay
Analogue Input
MTL4541 1ch 2/3 wire Transmitter repeater
MTL4541A 1ch Transmitter repeater, passive input
MTL4541AS 1ch Transmitter repeater, passive input, current sink
MTL4541B MTL4041B replacement
MTL4541P MTL4041P replacement
MTL4541S 1ch 2/3 wire Transmitter repeater, current sink
MTL4544 2ch 2/3 wire Transmitter repeater
MTL4544A 2ch Transmitter repeater, passive input
MTL4544AS 2ch Transmitter repeater, passive input, current sink
MTL4544B MTL4044 replacement
MTL4544D 2/3 wire transmitter repeater, dual output
MTL4544S 2ch 2/3 transmitter repeater, current sink
Analogue Output
MTL4546 1ch 4-20mA smart isolating driver + LFD
MTL4546C 1ch 4-20mA smart isolating driver + oc LFD
MTL4546Y 1ch 4-20mA smart isolating driver + oc LFD
MTL4549 2ch 4-20mA smart isolating driver + LFD
MTL4549C 2ch 4-20mA smart isolating driver + oc LFD
MTL4549Y 2ch 4-20mA smart isolating driver + oc LFD
Temperature Input
MTL4575 1ch Temperature converter with alarm
MTL4576-RTD 2ch Temperature converter, RTD
MTL4576-THC 2ch Temperature converter, THC
MTL4581 1ch mV/THC isolator for low-level signals
Pulse and Vibration
MTL4531 1ch vibration probe interface
MTL4532 1ch pulse isolator, digital or analogue output
MTL4533 2ch vibration probe interface
Fire and Smoke
MTL4561 2ch loop-powered, for fire and smoke detectors
General
MTL4599 Dummy isolator
MTL4599N General purpose feed-through module
Functional Safety Management (FSM)
Many MTL products are certified as safe for use in hazardous areas; that is places where explosive material may be present. The products are designed and certified to show that they are incapable of igniting the gas or dust and causing fire or explosion.
Another type of safety is called Functional Safety, which applies when products are used in safety and protection systems, in which a failure may mean that a protective system will not operate as it should. MTL products have been used in safety systems for some time, but there are increasing requirements to demonstrate an adequate level of functional safety, especially after the Buncefield, Texas City and Deepwater Horizon accidents. More and more, customers are demanding that products they use in safety systems meet the requirements of the second edition of the IEC 61508 Functional Safety standard, and they require evidence to show that they do. This is to enable the use of our products within instrumentation loops that are designed to achieve a specific Safety Integrity Level (SIL).
When MTL designs a product in the expectation that it will be used in functional safety-related systems, both the design process and the product needs to comply with IEC 61508:2010.
MTL has chosen to obtain Functional Safety Management (FSM) certification for the company. FSM means that MTL has the necessary processes and competence to design products according to IEC 61508:2010. Certification means that a notified body is ensuring that our processes are correct and that we are working to them. Together, FSM Certification gives our customers confidence in the company and the use of our products for functional safety.