Place of Origin: | UK |
Brand Name: | MTL |
Certification: | CE |
Model Number: | MTL4840 Series |
Minimum Order Quantity: | 10 Pcs |
---|---|
Price: | according to the purchase quantity |
Packaging Details: | carton |
Delivery Time: | in stock |
Payment Terms: | T/T payment |
Supply Ability: | 200 Pcs |
MTL4840 Series communicate with, configure and monitor HART® smart devices in safe and hazardous areas
I. SIL3 rating
II. Connect up to 7936 loops to a single PC
III. LED indication of loop being scanned
The MTL4840 HART® connection system provides a simple interface between smart devices in the field and HART® instrument management software run on a PC.
The system is based on 16-channel modularity to provide a compact, easily configurable and expandable system. Using a standard RS485 serial link, up to 7936 individual HART® devices can be connected to a single workstation.
For the optimum solution, choose from a range of general purpose and IS termination boards. For maximum flexibility the BPHM64 HART® backplane locates an MTL4841 communications module and up to four MTL4842 interface modules. General purpose HART® connection units and IS backplanes are also available, each fitted with an interface cable for connection to the BPHM64 HART® backplane.
MTL4841 and MTL4842 modules can also be located on HMU16 termination boards for general purpose applications or on BPMH16 / BPMH16U / BPSH16 / BPSH16-32 backplanes for IS isolator
requirements.
The DIN-rail mounting HCU16 and HCU16AOHART® connect to 16 general purpose field instruments while maintaining channel to channel isolation. Resistor conditioning options are compatible with all I/O cards. It allows pass-through connections for transmitter power supply, input signal and common.
I. Easily scalable modular system
II. Compact, ideal for new projects and upgrades
III. Channel to channel isolation option
The HCU16AO unit includes HART® filters for I/O cards incompatible with HART® signals. BPMH16/BPMH16U/BPSH16/BPSH16-32 backplanes with MTL4840 HART® modules fitted, connect either 16 or 32 IS field instruments. Adapter cards are available for the BPMH16U for easy integration to I/O cards and users have a choice of a DIN-rail mounting option.
Numerous features may be included in the connection units and backplanes, as required.
Channel to channel isolation; resistors where required for HART® signal conditioning; and HART® filters for analogue systems where the output signal interferes with HART® data or becomes unstable with the presence of the HART® signal.
Customised backplanes and connection units are available to provide direct connection from DCS I/O cables, replacing the standard termination board.
MTL HART multiplexers are certified by BASEEFA as a safety related sub-system to IEC61508. See the SR Series Interfaces section of this catalogue.
MTL4840 SERIES MODULE SPECIFICATIONS
MTL4841 COMMUNICATIONS MODULE
Host system interface
RS485 2-wire multidrop
Up to 31 MTL4841 modules can be connected to one host station
Unit address: switch-selectable on top of module
Isolation
RS485 output isolated from backplane power supply
Serial communication parameters
RS485 Baud rate: 1.2, 9.6, 19.2, 38.4kbaud, switch- selectable on top of module
RS485 highway length: up to 1km
MTL system interface
Links with up to 16 MTL4842 HART® interface modules via interface bus on backplane/ribbon cable
LED indicators
Green: one provided for power and status indication
Power requirements
Powered from backplane
Power consumption
<1.0W
Instrument management software supported
See 'Instrument management software'
MTL4842 HART® INTERFACE MODULE
MTL systems interface
Links up to 16 loops via backplanes
Receives multiplexer control signals via interface bus from MTL4841 and selects one channel for communication
Unit address
Switch selectable on top of module
Interface bus
Total length of interface bus between module 1 and module 16 must not exceed 4m
LED indicators
Green: one provided for power
Amber: one to indicate unit is selected by MTL4841
Red: four to identify loop address
Power requirements
Powered from backplane
Power consumption
<0.1W
MTL4000 SERIES MODULES
(See 'MTL4000 Series' for detailed specifications and circuit diagrams)
MTL4041A: Current repeater, 4/20mA, passive input for smart transmitters
MTL4041B: Repeater power supply, 4/20mA, for 2- or 3-wire transmitters
MTL4041P: High power repeater power supply, 4/20mA, for 2- or 3-wire transmitters
MTL4044: Repeater power supply, 4/20mA, two channel, for 2 wire transmitters
MTL4046/C: Isolating driver, for HART® valve positioners
MTL4046P: High power isolating driver for HART® valve positioners
COMMON SPECIFICATION
(applies to all MTL4840 and 4000 Series modules)
Location of units
Safe area (MTL4840 can be located in Div2)
Long-term drift
No recalibration necessary
Ambient temperature limits
–20 to +60°C continuous working
–40 to +80°C storage
Humidity
5 to 95% RH (non-condensing)
Sell MTL5511 Barrier Manufactured by MEASUREMENT TECHNOLOGY LTD
Sell MTL5513 Barrier Manufactured by MEASUREMENT TECHNOLOGY LTD
Sell MTL5514 Barrier Manufactured by MEASUREMENT TECHNOLOGY LTD
Sell MTL5544D Barrier Manufactured by MEASUREMENT TECHNOLOGY LTD
MTL5516C SWITCH/ PROXIMITY DETECTOR INTERFACE 2-CHANNEL, WITH LINE FAULT DETECTION
MTL5525 SOLENOID/ALARM DRIVER SWITCH OPERATED WITH OVERRIDE, IIC, LOW POWER
MTL5514D SWITCH/ PROXIMITY DETECTOR INTERFACE 1-CHANNEL, DUAL OUTPUT, LFD, PHASE REVERSAL
MTL5544D REPEATER POWER SUPPLY SINGLE CHANNEL, 4/20MA, HART® FOR 2- OR 3-WIRE TRANSMITTERS
MTL7743 2 channel proximity sensor or switch input and relay outputs
MTL7743 2 channel proximity sensor or switch input and relay outputs
MTL7745 proximity sensor or switch input with relay output and line fault detect
MTL7742 proximity sensor or switch input with solid state output